1.
Braz. oral res. (Online) ; 32: e104, 2018. tab, graf
Article in English | LILACS | ID: biblio-974458

ABSTRACT

Abstract This study evaluated the three-year lifespan of the bond to dentin of experimental self-etch adhesives containing benzodioxole derivatives - 1,3-benzodioxole (BDO) and piperonyl alcohol (PA) - as co-initiator alternative to amines. Adhesive resins were formulated using Bis-GMA, TEGDMA, HEMA, camphorquinone and different co-initiators: BDO, PA or ethyl 4-dimethylamino benzoate (EDAB - amine). An experimental self-etch primer was used to complete the two-step, self-etch adhesive system. Clearfil SE Bond (CSE) was used as commercial reference. Bond strength to human dentin was assessed by microtensile bond strength (µTBS) test, and failure mode was classified. Morphology of the dentin bonding interface was assessed via scanning electron microscopy (SEM). Irrespective of the dental adhesives evaluated, µTBS was higher after 24 hours compared with that after 1.5 and 3 years (p ≤ 0.001). However, adhesives with BDO and PA as co-initiators showed significantly higher bond strength than the bonding resin with EDAB (p ≤ 0.002), independent of the time evaluated. The commercial adhesive CSE showed similar bond strength compared with the other groups (p ≥ 0.05). Mixed failures were mainly observed after 24 hours, while adhesive failures were more frequently observed after 1.5 and 3 years. No notable differences in homogeneity and continuity along the bonded interfaces were detected among the materials in the SEM analysis. In conclusion, benzodioxole derivatives are feasible alternative co-initiators to tertiary amine in camphorquinone-based self-etching dental adhesive formulations.


Subject(s)
Humans , Benzyl Alcohols/chemistry , Dentin-Bonding Agents/chemistry , Resin Cements/chemistry , Dentin/drug effects , Dioxoles/chemistry , Benzodioxoles/chemistry , para-Aminobenzoates/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Surface Properties , Tensile Strength , Time Factors , Materials Testing , Camphor/analogs & derivatives , Camphor/chemistry , Microscopy, Electron, Scanning , Reproducibility of Results , Dental Bonding/methods , Bisphenol A-Glycidyl Methacrylate/chemistry , Dentin/chemistry , Methacrylates/chemistry
2.
RGO (Porto Alegre) ; 65(1): 8-12, Jan.-Mar. 2017. tab
Article in English | LILACS | ID: biblio-842369

ABSTRACT

ABSTRACT Objective: The aim of this study is to analyze if both color and nylon fibers have an influence on microwave-cured acrylic resin properties. Methods: Rectangular and disk-shaped specimens were prepared using acrylic resins; medium pink with and without nylon fibers and colorless without nylon fibers. To obtain the rectangular specimens, a stainless steel die was used with the following dimensions: 64 X 10 x 3 mm (± 0.5mm). To obtain disk-shaped specimens, a die 50mm (±0.5mm) in diameter and 0.5mm (±0.05mm) thick was employed. They were randomized to form groups: control (colorless acrylic) and experimental (medium pink, with and without nylon fibers), with each group consisting of ten (10) specimens rectangular in shape and five (5) disk-shaped. They were analyzed in six (6) assays (izod impact strength, n=10; Knoop hardness, n=10; glass transition temperature, n=3; water sorption and solubility, n=5; degree of monomer/polymer conversion, n=1; flexural strength and flexural modulus, n=10). All variables were subjected to the analysis of variance test followed by Tukey's multiple comparison test, at a 5% level of significance. Results: The analysis of the monomer/polymer degree of conversion did not reveal any difference between the three groups of resins (medium pink, with and without nylon fibers and colorless resin); it was approximately 88%. The results did not show significant differences between the groups for each variable (p>0.05). Conclusion: The results showed that color and presence of nylon fibers in acrylic resins did not affect the properties analyzed in this study.


RESUMO Objetivo: Analisar se corantes e fibras de nylon influenciam nas propriedades de uma resina acrílica ativada por energia de micro-ondas. Métodos: Espécimes retangulares e em forma de disco foram confeccionados em resina acrílica rosa médio com e sem fibras de nylon e incolor sem fibras. Para obter os espécimes retangulares, foi utilizada uma matriz de aço inoxidável com as seguintes dimensões: 64 X 10 X 3 (± 0,5mm) e para obter os espécimes em forma de disco, foi utilizada uma matriz com 50mm (± 0,5mm) de diâmetro e 0,5mm (±0,05mm) de espessura. Os mesmos foram randomizados para formar os grupos controle (acrílico incolor sem fibras) e experimentais (rosa médio com e sem fibras), sendo cada grupo composto por dez (10) espécimes retangulares e cinco (5) em forma de disco. Foram os mesmos então submetidos a seis (6) ensaios (resistência ao impacto izod, n=10; dureza knoop, n=10; temperatura de transição vítrea, n=3; sorção e solubilidade, n=5; grau de conversão, n=1; resistência à flexão e módulo de flexão, n=10). Todas as variáveis foram submetidas à análise de variância seguida pelo teste de comparações múltiplas de Tukey, com nível de significância de 5%. Resultados: O grau de conversão foi de 88% para os 3 grupos de resinas e os resultados não mostraram diferença estatisticamente significativa entre os mesmos para cada variável (p>0,05). Conclusão: Os resultados mostraram que o corante e a presença de fibras de nylon em resina acrílica não afetaram as propriedades analisadas nesse estudo.

3.
RGO (Porto Alegre) ; 63(3): 315-318, July-Sept. 2015.
Article in English | LILACS | ID: lil-765052

ABSTRACT

Objective: The objective of this study was to evaluate the effectiveness of disinfection methods in microwave and immersion in peracetic acid in heat-cured, self-cured and microwave-cured acrylic resin, contaminated with Candida albicans.Methods: Five specimens were prepared for each type of acrylic resin. All were infected with Candida Albicans, incubated at 37°C for 24 hours. The group which underwent microwave energy was irradiated with a power of 840W for 1 minute and the other group underwent disinfection by soaking of 0.2% peracetic acid for 5 minutes.Results: All samples proved to be contaminated after the incubation period. After the different processes of disinfection, both immersion in 0.2% peracetic acid as microwave irradiation were effective in disinfection of the 3 types of acrylic resins contaminated by Candida Albicans.Conclusion: Concluded that soaking in 0,2% peracetic acid for 5 minutes with microwave irradiation power 840W for 1 minute are effective methods for disinfecting heat-cured acrylic resin, self-cured acrylic resin and microwave-cured acrylic resin, contaminated with Candida Albicans.


Objetivo: Avaliar a eficácia dos métodos de desinfecção em microondas e imersão em ácido peracético em resina acrílica termopolimerizável, autopolimerizável e resina acrílica polimerizada por microondas, contaminadas com Candida albicans.Métodos: Cinco amostras foram preparadas para cada tipo de resina acrílica. Todas foram infectadas com Candida Albicans, incubadas a 37 ° C durante 24 h. O grupo submetido a energia de microondas foi irradiada com uma potência de 840W durante 1 minuto e o outro grupo foi submetido a desinfecção por imersão de ácido peracético a 0,2% durante 5 minutos.Resultados: Todas as amostras mostraram estar contaminadas depois do período de incubação. Depois dos diferentes processos de desinfecção, tanto a imersão em 0,2% de ácido peracético, como a irradiação de microondas foram eficazes na desinfecção dos 3 tipos de resinas acrílicas contaminados por Candida Albicans.Conclusão: Concluiu-se que a imersão em ácido peracético 0,2% durante 5 minutos e a irradiação de microondas com potência de 840W durante 1 minuto são métodos eficazes para a desinfecção de resina acrílica termopolimerizável, resina acrílica autopolimerizável e resina acrílica polimerizada por microondas, contaminados com Candida Albicans.

4.
Braz. j. oral sci ; 6(21): 1353-1356, Apr.-June 2007. tab, graf
Article in English | LILACS, BBO | ID: biblio-850539

ABSTRACT

The aim of this study was to evaluate the influence of powder/liquid ratio in the diametral tensile strength of two resin-modified glass ionomers cements (RMGIC). Two Brazilian brands of RMGIC: Resiglass R (RG: Biodinâmica) and Vitro Fil LC (VF: DFL) were used. Each product was mixed in two different powder/liquid ratios, (1:1) 1 scoop of powder to one drop of liquid or (1:2) 1 scoop of powder to 2 drops of liquid. The control was considered the powder/liquid ratio recommended by each manufacturer (RG 1:1 and VF 1:2 P/L). Four groups (n=5) with sample dimensions of 2.5 and 5.0 mm (thickness and diameter respectively) were tested. Diametral Tensile Test was performed in a mechanical testing machine (EMIC DL 500). Data obtained were submitted to One-way ANOVA and Tukey's multiple comparisons test (α=5%). For both national RMGICs, the experimental variations in the powder/liquid ratio led to an increase in diametral tensile strength when compared to the ratios advocated by the manufacturers. Group VL manipulated with experimental ratio1:1 showed statistically the highest (25.54±2.38 MPa) DTS mean among the tested groups whereas Resinglass R manipulated with 1:1 ratio, as advocated by manufacturer, showed statistically the lowest DTS mean (9.27±1.37 MPa). A review and further adjustments in the ratios recommended by the manufacturers of both resin-modified glass ionomers cements investigated is necessary.


Subject(s)
Dental Cements , Glass Ionomer Cements , Tensile Strength , Dental Materials
5.
RFO UPF ; 11(1): 73-77, 2006. tab
Article in Portuguese | LILACS, BBO | ID: lil-457214

ABSTRACT

A proposta deste estudo foi avaliar a influência de um ciclo de aquecimento em forno de microondas, indicado para desinfecção, sobre a microdureza Knoop e a temperatura de transição vitrea (Tg) de três tipos de resinas acrílicas: termopolimerizável (Classico, Art. Classico, jet, Art, Classico, São Paulo, SP) e polimerizada por energia de microondas (Onda-Cryl, Art, Classico, São Paulo, SP). Para o ensaio de microdureza, foram confeccionados quatro corpos-de-prova de cada tipo de resina acrílica , com 2,2 cm de lado e 2 mm de espessura. Após a obtenção das médias de microdureza, os corpos-de-prova foram submetidos ao ciclo de aquecimento em forno de microondas por um minuto a 850W, sendo então novamente avaliados quanto à microdureza. Para a obtenção da Tg (C), determinada por meio da calorimetria exploratória diferencial (DSC), foram confeccionados seis corpos-de-prova para cada tipo de resina acrílica, nas mesmas dimensões anteriores, sendo três utilizados como controle e três submetidos ao ciclo de aquecimento em forno de microondas durante um minuto a 850W. Os dados foram submetidos ao teste t de Student pareado e os Tg, ao teste t de Student não pareado. Os resultados mostraram um aumento significativo na microdureza para a resina polimerizada por energia de microondas e uma diminuição significativa da Tg para a resina acrílica termopolimerizável. É possivel concluir que um ciclo de aquecimento em forno de microondas aumentou a microdureza da resina de microondas testada e diminuiu a Tg da resina termopolimerizável, servindo de alerta para avaliar com maior cuidado a relação custo/benefício da técnica proposta


Subject(s)
Acrylic Resins , Disinfection , Hardness , Microwaves , Transition Temperature
6.
Rev. ciênc. farm ; 23(2): 277-287, 2002. ilus, tab
Article in Portuguese | LILACS | ID: lil-342409

ABSTRACT

Métodos quantitativos de análise do aciclovir por volumetria em meio não-aquoso são comparados com o método oficial. As propriedades anfotéricas do fármaco, devido aos dois valores de pKa da molécula, possibilitam sua determinação, tanto como ácido quanto como base fraca, com uso de indicadores, tais como cristal violeta, naftolbenzeína e azovioleta, desde que a matéria-prima seja devidamente dessecada pelo menos a 160°C, durante 2 horas. Os resultados obtidos indicam que os métodos avaliados são exatos e precisos, constituindo-se em alternativa para o método oficial.


Subject(s)
Humans , Acyclovir
SELECTION OF CITATIONS
SEARCH DETAIL